Gill Technology's MicroFlow uses proven ultrasonic
techniques to measure gas flow accurately and reliably
with no moving parts.
The Microflow demonstrates for the first time in a single unit, the measurement
of bi-directional gas flow. Together with its high sample rate and accuracy the
MicroFlow is able to deliver detailed information of very small changes in gas
flow.
Specifications
| Size |
145 x 135 x 30mm (LxWxH) |
| Mass Flow Range |
0 to 600kg/hour |
| Measurement Rate |
100 per second |
| Flow Range |
0.01 to 1000 ml/minute |
| Resolution |
0.01 ml/minute |
| Pressure Range |
0 to 7.0 bar gauge |
| Accuracy |
±3% or ±2ml/minute |
| Average Offset |
±0.5 ml/minute |
| Supply Voltage |
12V |
| Supply Current |
150mA max |
| Operational Temperature |
-10°C to +60°C |
| Storage Temperature |
-20°C to +70°C |
| Humidity |
95% RH (no condensation) |